Hearth Requirements - Quadra-Fire CB1200M-MBK Installation And Operation Maintenance

Classic bay 1200 pellet stove
Hide thumbs Also See for CB1200M-MBK:
Table of Contents

Advertisement

CB 1200 Pellet Stove
C. Hearth Pad Requirements (UL and ULC)
Use a non-combustible fl oor protector, extending beneath
appliance and to the front, sides and rear as indicated.
Measure front distance "M" from the surface of the glass
door.
K
Figure 10.1
Hearth Pad Requirements
K
Sides
Back
L*
M
Front
*L Exception for Horizontal Installations:
USA INSTALLATIONS: A non-combustible fl oor protec-
tion is recommended extending beneath the fl ue pipe
when installed with horizontal venting or under the top
vent adapter with vertical installation.
CANADA INSTALLATIONS:
protection extending beneath the fl ue pipe is required
with horizontal venting or under the top vent adapter with
vertical installation.
Must extend 2 inches (51mm) beyond each
side of pipe (shaded area)
Figure 10.2
Page 10
L*
K
M
Inches
Millimeters
2
51
2
51
6
152
A non-combustible fl oor
7014-179K
R
May 6, 2015