Clearances To Combustibles; Hearth Pad Requirements - Quadra-Fire MTVERNON-AE-MBK Owner's Manual & Installation

Mt. vernon pellet stove advanced energy
Hide thumbs Also See for MTVERNON-AE-MBK:
Table of Contents

Advertisement

Mt. Vernon Pellet Stove (AE)
B. Clearances to Combustibles (UL and ULC)
A
B
Straight Back Against Wall
A
Back Wall to Appliance
B
Side Wall to Appliance
Corner Installation
C
Walls to Appliance
Installations with:
3 to 3 inch Top Vent Adapter and
3 to 6 inch Offset Adapter Kit
F
D
E
Vertical Installation
D
Back Wall to Flue Pipe
E
Side Wall to Appliance
F
Back Wall to Appliance
Corner Installation
G
Side Wall to Flue Pipe
Alcove Installation
Minimum Alcove Height
Minimum Alcove Side Wall
Minimum Alcove Width
Maximum Alcove Depth
NOTE:
Illustrations refl ect typical installations and are FOR
DESIGN PURPOSES ONLY.
Illustrations/diagrams are not drawn to scale.
Actual installation may vary due to individual design
preference.
Page 8
C
C
Inches
Millimeters
2
51
6
152
Inches
Millimeters
2
51
G
G
Inches
Millimeters
3
76
6
152
8
203
Inches
Millimeters
3
76
Inches
Millimeters
43
1092
6
152
40
1016
36
914
7034-106B
C. Hearth Pad Requirements (UL and ULC)
Use a non-combustible fl oor protector, extending beneath
appliance and to the front, sides and rear as indicated.
Measure front distance "M" from the surface of the glass
door.
K

Hearth Pad Requirements

K
Sides
L*
Back
M
Front
*L Exception for Horizontal Installations:
USA INSTALLATIONS: A non-combustible fl oor protec-
tion is recommended extending beneath the fl ue pipe
when installed with horizontal venting or under the Top
Vent Adapter with vertical installation.
CANADA INSTALLATIONS:
protection extending beneath the fl ue pipe is required
with horizontal venting or under the Top Vent Adapter with
vertical installation.
Must extend 2 inches (51mm) beyond each
side of pipe (shaded area)
WARNING
Fire Risk.
Comply with all minimum clearances to
combustibles as specifi ed.
Failure to comply may cause house fi re.
L*
K
M
Inches
Millimeters
2
51
2
51
6
152
A non-combustible fl oor
December 22, 2006
R

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mtvernon-ae-pmhMtvernon-ae-csbMtvernon-ae-cwl

Table of Contents