Limited International Polar Guarantee - Polar Electro RCX5 User Manual

Training computer
Hide thumbs Also See for RCX5:
Table of Contents

Advertisement

ENGLISH
Reset the training computer by pressing all the buttons simultaneously for two seconds until the display
fills with digits. Press any button, select language and set the time and date in Basic Settings after the
reset. All other settings are saved. Skip the rest of the settings by pressing and holding BACK.
...the heart rate reading becomes erratic, extremely high or shows nil (00)?
• Make sure the transmitter belt has not loosened during exercise.
• Make sure the textile electrodes in the sports apparel fit snugly.
• Make sure that the electrodes of the transmitter are moistened.
• Make sure the transmitter is clean. Strong electromagnetic signals can cause erratic readings. For further
information, see Precautions (page 53).
• If the erratic heart rate reading continues despite moving away from the source of disturbance, slow down
your speed and check your pulse manually. If you feel it corresponds to the high reading on the display,
you may be experiencing cardiac arrhythmia. Most cases of arrhythmia are not serious, but consult your
doctor nevertheless.
• A cardiac event may have altered your ECG waveform. In this case, consult your physician.
...
Check heart rate transmitter!
signal?
• Make sure the transmitter belt has not loosened during exercise.
• Make sure that the electrodes of the transmitter are moistened.
• Make sure the transmitter electrodes are clean and undamaged.
If you have done all of the above-mentioned actions, and the message still appears and heart rate
measurement does not work, the battery of your transmitter may be empty. For further information, see
Important Information (page 51).
...
is displayed?*
Calibration failed
Calibration did not succeed and you need to re-calibrate. Calibration fails if you move during the process.
Once you reach lap distance, stop running and stand still for calibration. The range of the calibration
factor during manual calibration is 0.500-1.500. If you have defined the calibration factor below or above
these values, calibration fails.
*Optional s3+ stride sensor required.
...
is displayed?
Memory 90...99% full
is displayed when there is approximately 1 hour of memory left. To maximize the
1 hour of memory left
remaining memory capacity, select the longest recording rate (1 minute) from
. Once the memory has been depleted
Recording rate
the training files to polarpersonaltrainer.com and delete them from the wrist unit memory.
ZoneOptimizer determination fails?
• Make sure that the electrodes of the transmitter are moistened.
• Make sure the transmitter belt has not loosened during exercise.
• Make sure the transmitter electrodes are clean and undamaged.
• Make sure you have followed the instructions carefully.
If you have done all of the above-mentioned actions, and the message still appears and heart rate
measurement does not work, the battery of your transmitter may be empty. For further information, see
Important Information (page 51).

Limited International Polar Guarantee

• This guarantee does not affect the consumer's statutory rights under applicable national or state laws in
force, or the consumer's rights against the dealer arising from their sales/purchase contract.
56
Important Information
is displayed and your training computer cannot find your heart rate
Memory full
>
SETTINGS
GENERAL SET.
is displayed. To free memory transfer
>

Advertisement

Table of Contents
loading

Table of Contents