Op Panel Cable; Logo Cover - Lexmark X543 Service Manual

Hide thumbs Also See for X543:
Table of Contents

Advertisement

Op panel cable

1.
Remove the operator panel bezel cover.
2.
Remove the operator panel. See
3.
Remove the flatbed assembly. See
4.
Remove the CCD cable cover.
5.
Unroute the operator panel cable through the tabs (B).
Warning: When replacing the op panel and USB cables, the cables must be routed in the exact same route with
no overlapping of the cables. Failure to do so can result in the crimping of the cables. In addition,
the redrive unit on the scanner might not make proper contact with the redrive rolls on the top cover.
This could result in a paper jam under the flatbed unit.

Logo cover

1.
Remove the op panel bezel cover. See
2.
Use a flatbed screwdriver to depress the four tabs (A) securing the logo cover to the op panel bezel cover.
"Operator panel removal" on page
"Flatbed removal" on page
A
"Op panel bezel removal" on page
A
4-98.
4-72.
B
7525-xxx
4-100.
4-101
Repair information

Advertisement

Table of Contents
loading

This manual is also suitable for:

X546X544