Removal Of Electrical Box - Daikin FTXS20G2V1B Service Manual

G-series
Hide thumbs Also See for FTXS20G2V1B:
Table of Contents

Advertisement

SiENBE04-808_A
2.2

Removal of Electrical Box

Procedure
Step
1
Disconnect the 2
connectors for the
reactor.
2
Cut the clamps at 2
locations.
3
Disconnect the
connector for the
compressor [S30].
Removal Procedure
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Procedure
[S30]
Outdoor Unit - RK(X)S20-35G2V1B, ARXS20-35G2V1B
Preparation
„ Remove the panels and
disconnect the connector for
the fan motor according to
the "Removal of Outer
Panels / Fan Motor".
(R9338)
(R9339)
„ When reassembling, coil the
excessive lead wire and
hang the loop on the hook.
(R9340)
Points
192