Main Circuit Short Check - Daikin FTXS20G2V1B Service Manual

G-series
Hide thumbs Also See for FTXS20G2V1B:
Table of Contents

Advertisement

Check

5.1.13 Main Circuit Short Check

Check No.29
Note:
Check to make sure that the voltage between (+) and (–) of the diode bridge (DB1) is approx.
0 V before checking.
„ Measure the resistance between the pins of the DB1 as below.
„ If the resistance is ∞ or less than 1 kΩ, short circuit occurs on the main circuit.
(–) terminal of the tester
(in case of digital,
(+) terminal)
(+) terminal of the tester
(in case of digital,
(–) terminal)
Resistance in OK
Resistance in NG
20/25/35 class
42 class
153
~
+
(2, 3)
(4)
+
~
(4)
(2, 3)
several kΩ
~ several MΩ
0 Ω or
0
SiENBE04-808_A
~
(1)
(2, 3)
~
(1)
(2, 3)
several kΩ
~ several MΩ
0 Ω or
0
1
Tester
2
3
4
(R12035)
1
Tester
2
3
4
(R12266)