CORNER POSITIONING (45°)
CORNER POSITIONING (45°) - 31M and 31LE
Fig. 4
Table 2
A
Min. clearance from fi rebox corner to corner walls
B
Min. distance from center of spigot to corner walls
C
Min. distance from corner wall to fl oor protector front
D
Min. fl oor protector projection from corner wall
E
Min. fl oor protector front width
F
Min. overall fl oor protector depth
1. If a separate fl oor protector is being used position now. Place the fi rebox on the fl oor protector to
suit the minimum installation clearances. (See Fig 3 or 4).
2. Seismically restrain the fi rebox and the fl oor protector to the fl oor.
3. Fit 2 x 6mm fi xings suitable for the fl oor material. DO NOT over tighten.
4. Fit timber trim pedestal edging to front and back of base (optional).
March 4, 2015
B
F
FLOOR PROTECTOR
DESCRIPTION
Pioneer Double Flue Mounted Shield Universal
Shall be Fitted

FIREBOX INSTALLATION

7033-308D
3100 Series ACC Wood Burner
A
E
C
D
With Double
Flue Shield
Fitted
225mm
532mm
1322mm
756mm
800mm
1469mm
Page 5