Hearth Protection Requirements; Firebox Installation - Quadra-Fire 43ST-ACC-AU Installation Manual

Hide thumbs Also See for 43ST-ACC-AU:
Table of Contents

Advertisement

B. Hearth Protection Requirements
Quadra-fire 4300 Step Top do not require a insulating Floor
Protector, as they are tested and comply with the minimum
Floor Protector requirements of AS/NZS 2918:2001.
NOTE:
• The minimum Floor Protector sizes are specified in
the clearance chart, see Figures 11.1, 11.2 & 11.3.
• A Floor Protector can include ceramic tiles with
grouted joints fixed directly onto a wooden floor or a
sheet of toughened glass, panel steel or any other non
combustible material laid directly onto a wooden floor.
• If installed directly onto a concrete slab, the concrete
slab can be considered as the floor protector,but must
maintain the minimum measurement listed.
Fire Risk.
Hearth pads must be installed exactly as
specified. High temperatures or hot embers
may ignite concealed combustibles.
Fire Risk.
• Comply with all minimum clearances to
combustibles as specified.
• Failure to comply may cause house fire.
10
WARNING
WARNING
C. Firebox Installation
1. If a separate floor protector is being used position
now. Place the firebox on the floor protector to suit the
minimum installation clearances Figures 11.1, 11.2 &
11.3.
2. Systemically restrain the firebox and the floor protector
to the floor.
3. Fit 2mm x 6mm fixings suitable for the floor material. DO
NOT over tighten.
7037-806A
05/21