B. Hearth Protection Requirements
Quadra-fire 3100 Millennium ACC do not require a
insulating Floor Protector, as they are tested and comply
with the minimum Floor Protector requirements of AS/NZS
2918:2001.
NOTE:
-
The minimum Floor Protector sizes are specified
in the clearance chart, see Figure 9.1 and
Figure 9.2 on page 9.
-
A Floor Protector can include ceramic tiles with
grouted joints fixed directly onto a wooden floor
or a sheet of toughened glass, panel steel or any
other non combustible material laid directly onto
a wooden floor.
-
If installed directly onto a concrete slab, the
concrete slab can be considered as the floor
protector,but must maintain the minimum
measurement listed.
WARNING
Fire Risk.
Hearth pads must be installed exactly as
specified. High temperatures or hot embers
may ignite concealed combustibles.
WARNING
Fire Risk.
Comply with all minimum clearances to
combustibles as specified.
Failure to comply may cause house fire.
8
C. Firebox Installation
1. If a separate floor protector is being used position
now. Place the firebox on the floor protector to suit
the minimum installation clearances (Figures 9.1 and
Figure 9.2 on page 9).
2. Systemically restrain the firebox and the floor protector
to the floor.
3. Fit 2mm x 6mm fixings suitable for the floor material.
DO NOT over tighten.
4. Fit timber trim pedestal edging to front and back of
base (optional).
7033-361B
November, 2021