Daikin 2MXS40H2V1B Service Manual page 137

Inverter multi for 2 rooms h-series / g-series
Hide thumbs Also See for 2MXS40H2V1B:
Table of Contents

Advertisement

SiBE121123_A
1
ON/OFF BUTTON
Press the ON/OFF button to start or stop the system.
2
OPERATION LAMP
The operation lamp lights up during operation or
blinks if a malfunction occurs.
3
OPERATION MODE ICON
These icons indicate the current operation mode
(FAN, DRY, AUTOMATIC, COOLING, HEATING).
4
VENTILATION MODE ICON
These icons indicate the current ventilation mode
(HRV only) (AUTOMATIC, HEAT EXCHANGE,
BYPASS).
5
VENTILATION ICON
The ventilation icon appears when the ventilation is
adjusted with the ventilation amount button (HRV
only). Simultaneously, the ventilation amount is
indicated by the fan speed icon (see 22).
6
AIR CLEANING ICON
This icon indicates that the air cleaning unit (option) is
operational.
7
LEAVE HOME ICON
The leave home icon shows the status of the leave
home function.
ON
FLASHING
OFF
8
EXTERNAL CONTROL ICON
This icon indicates that another controller with higher
priority is controlling or disabling your installation.
9
CHANGE-OVER UNDER CENTRALISED
CONTROL ICON
This icon indicates that the change-over of the
installation is under centralised control assigned to
another indoor unit or optional cool/heat selector
connected to the outdoor unit (= master remote
controller).
10
DAY OF THE WEEK INDICATOR
The day of the week indicator shows the current
week day (or the set day when reading or
programming the schedule timer).
11
CLOCK DISPLAY
The clock display indicates the current time (or the
action time when reading or programming the
schedule timer).
12
MAXTEMPERATURE IMUM SET
The maximum set temperature indicates the
maximum set temperature when in limit operation.
13
MINIMUM SET TEMPERATURE
The minimum set temperature indicates the minimum
set temperature when in limit operation.
Remote Controller
Leave home is enabled
Leave home is active
Leave home is disabled
14
SCHEDULE TIMER ICON
This icon indicates that the schedule timer is enabled.
15
ACTION ICONS
These icons indicate the actions for each day of the
schedule timer.
16
OFF ICON
This icon indicates that the OFF action is selected
when programming the schedule timer.
17
INSPECTION REQUIRED
These icons indicate that inspection is required.
Consult your installer.
18
SET TEMPERATURE DISPLAY
This indicates the current set temperature of the
installation (not shown in LIMIT operation or in FAN or
DRY mode).
19
SETTING
Not used, for service purposes only.
20
AIR FLOW DIRECTION ICON
This icon indicates the air flow direction (only for
installations with motorised air flow flaps).
21
NOT AVAILABLE
is displayed whenever a non-installed option
is addressed or a function is not available.
22
FAN SPEED ICON
This icon indicates the set fan speed.
23
DEFROST/HOTSTART MODE ICON
This icon indicates that the defrost/hotstart mode is
active.
24
AIR FILTER CLEANING TIME ICON
This icon indicates the air filter must be cleaned.
Refer to the manual of the indoor unit.
25
ELEMENT CLEANING TIME ICON
This icon indicates the element must be cleaned
(
only).
26
VENTILATION MODE BUTTON
The ventilation mode button operates the
to the
manual for more details.
27
VENTILATION AMOUNT BUTTON
This button sets the ventilation amount; refer to the
manual for more details.
28
INSPECTION/TEST OPERATION BUTTON
Not used, for service purposes only.
29
PROGRAMMING BUTTON
This button is a multi-purpose button.
Depending on the previous manipulations of the user,
the programming button can have various functions.