Vent Terminations - Montigo H38DF-ST Indoor Installation, Operation & Maintenance Manual

Hide thumbs Also See for H38DF-ST Indoor:
Table of Contents

Advertisement

H(L)38DF-ST See-thru indoor Gas Fireplace
CAUTION!
Due to its high operating temperatures, the appliance should
be located out of traffic & away from furniture and draperies.
Children and adults should be alerted to the hazards
of the high surface temperature, which could cause
burns or clothing ignition.
Young children should be carefully supervised when
they are in the same room as the appliance.
Clothing or other flammable materials should not be
placed on or near the appliance.
CAUTION:
Do not obstruct, or attempt to conceal, the vent termination.
These actions will affect the operation of the fireplace, and may
be hazardous.
In heavy snow areas, take extra care to prevent snow buildup
from obstructing the vent termination.
Cautions:
Vent terminations can be very hot. If the termination is less than 7 feet
above a public walkway, it should be fitted with a certified Montigo
Heat Guard. (Part no. PTKOG).
Do not obstruct, or attempt to conceal the vent termination.
These actions will affect the operation of the fireplace, and may
be hazardous.
In heavy snow areas, take extra care to prevent snow buildup
from obstructing the vent termination.
Use Montigo Vinyl Heat Shield (Part no. VSS) when using on
applications with vinyl siding to guard against possible damage.
Installing Terminations with Built-In Frames
11
11
Figure 4a. Installing a PTO termination.
Page 6
Installation
1.
2.
Installing Terminations with MSR Frames
Figure 4b. Installing a PTO termination with the MSR frame.
1. Frame the termination opening to 12" x 12".
2. Fasten the termination to the studs using a minimum of 4 screws.
Installing Terminations with MOSR Frames
PTO-3F (5"/8")
Figure 4c. Installing a PTO termination with the MOSR frame.
1.
2. Fasten the MOSR frame to the interior side of the studs using a
3. Insert the termination into the MOSR frame as shown here, and
Installing Heat Guards over Terminations
PTO-3F (5"/8")
Figure 4d. Installing a PTO termination heat guard.
Frame the termination opening to 11" x 11".
Fasten the termination to the studs using a minimum of 4
screws.
12
12
MOSR
Frame the termination opening to 12" x 12".
minimum of 4 screws.
attach by screwing through the four pilot holes in the termination.
MSR
PTO-3F (5"/8")
12 12
12
PTKOG (5"/8")
Part No. XG0207 - 092109