Montigo H38DF PFC Installation & Maintenance Manual

Peninsula indoor residential gas fireplace
Table of Contents

Advertisement

Installation & Maintenance Manual
DANGER
Read and understand this manual. Improper installation, adjustment, alteration,
service or maintenance can cause serious injury, property damage or even death.
For assistance or additional information consult a qualified installer, service
agency or the gas supplier.
Glass doors on gas fireplaces are extremely hot while the fireplace is on and
remain hot even after the fireplace has been turned off. Safety screens are
available and can reduce the risks of severe burns. Please keep children away
from the fireplace at all times.
XG0816
CAUTION
®
C
US
Canadian Heating Products Inc. Langley, BC V4W 4A1 | Montigo Del Ray Corp. Ferndale, WA 98248
H38DF PFC
HL38DF PFC
HP38DF PFC
Peninsula
Indoor
Residential Gas
Fireplace
WARNING
Do not store or use gasoline or any other flammable vapors and liquids in the vicinity of
this or any other gas burning appliance. A fire or explosion my occur causing serious
injury, property damage or even death.
NOTICE
Installer: Leave this manual with the appliance. Do not remove.
Consumer: Retain this manual for maintenance and future reference. Do not Discard.
DANGER
Blank
IF YOU SMELL GAS
Blank
Flammable materials
Explosion risk
Toxic
Corrosive
Danger overhead crane
Fork lift trucks
High voltage
Do not try to light any appliance.
Blank
Flammable materials
Explosion risk
Toxic
Corrosive
Danger overhead crane
Fork lift trucks
High voltage
Do not touch any electrical switch; do not use any phone in your building.
General Warning
Laser Radiation
Biohazard
Oxidising
Hot surface
Danger of entrapment
Danger of death
Flammable materials
Explosion risk
Immediately call your gas supplier from a neighbor's phone. Follow the gas
Toxic
Corrosive
Danger overhead crane
Fork lift trucks
High voltage
General Warning
Laser Radiation
Biohazard
Oxidising
Hot surface
Danger of entrapment
Danger of death
Irritant
Slippery floor
Watch your step
Cutting
High temperatures
Glass hazard
Danger of suffocation
Blank
supplier's instructions.
General Warning
Laser Radiation
Biohazard
Oxidising
Hot surface
Danger of entrapment
Danger of death
Irritant
Slippery floor
Watch your step
Cutting
High temperatures
Glass hazard
Danger of suffocation
Gas bottles
Watch for
Electricity
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
Flammable materials
falling objects
Explosion risk
Toxic
Corrosive
Danger overhead crane
Fork lift trucks
High voltage
If you cannot reach your gas supplier, call the fire department.
Irritant
Slippery floor
Watch your step
Cutting
High temperatures
Glass hazard
Danger of suffocation
Gas bottles
Watch for
Electricity
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
Low temperature
Strong magnetic field
falling objects
Optical radiation
Non ionizing
Radiation
Hazardous to the
Danger of harming
radiation
Environment
your hands
General Warning
Laser Radiation
Biohazard
Oxidising
Hot surface
Danger of entrapment
Danger of death
Gas bottles
Watch for
Electricity
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
Low temperature
Strong magnetic field
falling objects
Optical radiation
Non ionizing
Radiation
Hazardous to the
Danger of harming
radiation
Environment
your hands
Irritant
Slippery floor
Watch your step
Cutting
High temperatures
Glass hazard
Danger of suffocation
Low temperature
Strong magnetic field
Optical radiation
Non ionizing
Radiation
Hazardous to the
Danger of harming
radiation
Environment
your hands
Gas bottles
Watch for
Electricity
Danger for cutter
Entrapment hazard
Battery hazard
Rotating parts
falling objects
011012.1

Advertisement

Table of Contents
loading

Summary of Contents for Montigo H38DF PFC

  • Page 1 Danger of harming radiation Environment your hands Gas bottles Watch for Electricity Danger for cutter Entrapment hazard Battery hazard Rotating parts falling objects XG0816 011012.1 Canadian Heating Products Inc. Langley, BC V4W 4A1 | Montigo Del Ray Corp. Ferndale, WA 98248...
  • Page 2: Table Of Contents

    H*38DF PFC Peninsula Gas Fireplace NOTICE You must read and understand this manual prior to installation, operation or troubleshooting this appliance. Please retain this owner’s manual for furure reference and maintenance. Table of Contents Safety Alert Key Section 4: .................3 Introduction Wiring ................18 Models...
  • Page 3: Safety Alert Key

    INTRODUCTION Congratulations on your purchase of a Montigo Fireplace. With over 30 years of experience, Montigo is committed to providing you with a gas fireplace that is not only a beautiful addition to your space, but that is also designed and manufactured to the highest safety, reliability and engineering standards.
  • Page 4: Installation

    Should it be impossible to meet the venting requirements laid „ BEFORE YOU START: out in Section 3: Venting, please contact a local Montigo dealer regarding the use of a Montigo Power Vent. Lay out the Vent run; calculating the required elbows and straight „...
  • Page 5: Section 1: Installation Overview And Product Dimensions

    H*38DF PFC Peninsula Gas Fireplace Installation Section 1: Installation Overview and Product Dimensions Safety, as well as efficiency of operation, should be considered when Please review the Installation Checklist on Page 4 for general information selecting the fireplace location. Select a location that does not interfere on preparing for a successful installation of your fireplace.
  • Page 6: Framing The Fireplace

    H*38DF PFC Peninsula Gas Fireplace Installation Section 2: Framing Frame in the enclosure for the unit with framing materials. The Top Vent framed opening for the assembled fireplace is 23 3/4" wide, x 44" Ceiling level high x 41" deep, see Figure 2 Non-Combustible materials.
  • Page 7: Clearances

    H*38DF PFC Peninsula Gas Fireplace Installation Nailing Flange Extension Clearances When installing a shelf over the top of the fireplaces, the following The 4" nailing flange extension is shipped attached to the top edge of the fireplace, see Figure 1. guidelines must be adhered to: For Rear Vent applications, the minimum clearance is 2"...
  • Page 8: The Direct Vent System

    Section 3: Venting 3. Install the (removed) Rear flue cover and gasket material, to the Montigo supplies a variety of direct venting and termination options. Top vent outlet. Fasten the cover with included hardware, as The direct vent termination location MUST be selected such that illustrated Figure 8a.
  • Page 9: Section 3-2: Installing A Roof Mounted Termination

    H*38DF PFC Peninsula Gas Fireplace Installation Section 3-2: INSTALLING A ROOF MOUNTED DIRECT VENT PVTK1 TERMINATION (PVTK-1) Termination This section applies to installations where the direct vent termi- 2’ min. nation will be roof mounted. Section 3-2-1: Support ring VENTING LAYOUT Selection of components and details of venting lay out should Support plate 32’...
  • Page 10: Standard Roof Vent (One Elbows No Offsets)

    H*38DF PFC Peninsula Gas Fireplace Installation PVTK1 Termination Support plate 32’ Ma. x Support ring 12” Max. Figure 9c. Rear vent, Roof mounted venting (1 = 90° bend). Page 10 XG0816 - 011012.1...
  • Page 11: Section 3-3: Installing A Wall Mounted Termination

    H*38DF PFC Peninsula Gas Fireplace Installation Section 3-3: 4). Installation of termination from inside structure INSTALLING A WALL MOUNTED DIRECT VENT TERMINATION A Termination with a MOSR Frame is installed from the inside of the This section applies to installations where the direct vent termi- structure.
  • Page 12: Section 3-3-1: Venting Layout

    Venting runs must fall within the limits set by the venting graph, „ please contact a local Montigo see Figure 12 or 12a dealer for Power Venting options. The Venting Graph: H*38PF* Measure the vertical height from the fireplace hearth to the centre of Figure 12a.
  • Page 13: Top Vent, Wall Mounted Termination (Multi Elbow)

    H*38DF PFC Peninsula Gas Fireplace Installation Heat 150” Max. Shield Termination Solid Section Flex Section Exterior Wall Hearth Figure 13b. H38PF* , HL38PF* or HP38PF* Top Vented, wall mounted Multi- elbow installation. See Venting Graph for Top vent, wall mounted terminations, Figure 12 or 12a.
  • Page 14: Rear Vent, Wall Mounted Termination Graph, H*38Pf

    12 ” contact a local Montigo dealer for the wall flange of the termination. Plot on the Venting Graph Figure 14 Power Venting options.
  • Page 15: Standard Rear Vent, (No Elbows Or Offsets)

    H*38DF PFC Peninsula Gas Fireplace Installation 42” Max. Flex or Rigid Section 20”Min. 53” Min. 12” Max. 33” Hearth Figure 15a. H38PF* or HL38PF* Rear Vented, wall mounted Multi-elbow termination installation. The vent run must comply with the Venting Graph for Rear vent, wall mounted terminations, Figure 14.
  • Page 16: Section 3-3-2: Venting Components

    FS-8 possible hot spots. H - Roof Flashing PRF-7 (1/12 - 7/12 pt.) Montigo recommends the use of a flex section for the final pipe „ PRF-12 (7/12 - 12/12 pt.) connected directly to the fireplace offering greater flexibility of installation and absorption of movement.
  • Page 17: Section 3-3-3: Heat Shields

    H*38DF PFC Peninsula Gas Fireplace Installation Section 3-3-3: Heat Shields Installing a Wall Mounted RHS101 Heat shield. Installing a Wall Mounted RHS8 Heat shield The RHS101 Heat shield MUST be used where the RHS8 Termination The RHS8 Heat shield CANNOT be used WITHIN 36" horizontal or (Figure 16 and 16a) CANNOT be used.
  • Page 18: Section 4: Wiring

    H*38DF PFC Peninsula Gas Fireplace Installation Section 4: Wiring Models Included H38DFPFCN-F HL38DFPFCN-F HP38DFPFCN-F H38DFPFCL-F HL38DFPFCL-F HP38DFPFCL-F Receiver 14 Battery Holder w/ Switch REMOTE ON/REMONTE/OFF Orange Pilot Green Receiver 14 Receiver 14 Pin Connector Battery Holder Top View (Not Used) RECEIVER 885 Valve SPLIT FLOW...
  • Page 19: Section 5: Installing The Gas Line

    1/8” N.PT. plug to be fitted with a hose barb. When pressure testing the fireplace, Gas line, and input system follow the appropriate Montigo requires a service shut off valve be located in an „ local codes or your area. DO NOT connect the fireplace to pressures in excess of 1/2lb.
  • Page 20: Finishing

    H*38DF PFC Peninsula Gas Fireplace Installation Finishing Around the Fireplace Mantels & Surrounds Combustible mantels and mouldings may be safely installed over the NOTE: National Canadian Gas Association mantel test requirements top and on the front of the fireplace provided that they do not project are for fire hazard prevention to combustible materials.
  • Page 21: Installing And Removing The Door

    H*38DF PFC Peninsula Gas Fireplace Installation Section 7: Installing & Removing the Door Removing the door: Step 5: The H*38PF* doors are removed in a few simple steps. Follow these instructions below to remove the Horizontal access panel, unlatch the Ensure the tool is firmly door buckles and, remove the door.
  • Page 22: Section 8: Installing The Accessories

    H*38DF PFC Peninsula Gas Fireplace Installation Section 8: Installing the Accessories Installing the H38PF* Logset The H38PF* is supplied with eight (8) fibre logs. The two small bottom Log C logs ("A" ) are mounted on the burner grate by placing them diagonally onto the supplied Log stands.
  • Page 23: Installing The Hl38Pf* Firestones

    H*38DF PFC Peninsula Gas Fireplace Installation Installing the HP38PF* Logs and Embers Bottom Logs The HP38PF* is supplied with seven (7) fibre logs. The two bottom logs Log F ("A" & "B") are mounted on the burner grate as shown in Figure 26a. Top Logs Place logs "C"...
  • Page 24: Installing The Hp38Pf* Log Set

    These may be spaced at random or in a visual pattern of your Figure 28a. Ensure ONLY one layer of firestones cover the preference in the burner pan. See the Montigo web site for photographs burner and no firestones cover the pilot.
  • Page 25: Operation

    H*38DF PFC Peninsula Gas Fireplace Operation Section 9: Start up Sequence Standing (Continuous) Pilot Ignition (SIT NOVA 820) with American Flame Electronic Ignition For Your Safety - READ BEFORE LIGHTING: WARNING If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death.
  • Page 26: Start-Up Sequence For Honeywell Electronic Ignition

    H*38DF PFC Peninsula Gas Fireplace Operation SIT Proflame Electronic Ignition with American Flame Electronic Ignition For Your Safety - READ BEFORE LIGHTING: WARNING If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. A.
  • Page 27: Start-Up Sequence For Proflame Sit Electronic Ignition

    H*38DF PFC Peninsula Gas Fireplace Operation Honeywell Electronic Ignition with American Flame Electronic Ignition For Your Safety - READ BEFORE LIGHTING: WARNING If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. A.
  • Page 28: Maintenance

    H*38DF PFC Peninsula Gas Fireplace Maintenance Lighting Instructions Hi-Lo Burner Adjustment: (SIT Nova 820). See pages 25 to 27. The H*38PF* is equipped with an adjustable burner, allowing you to General raise or lower the flames. To adjust the flames, locate the black knob Have the fireplace and installation inspected yearly.
  • Page 29: Troubleshooting

    If your fireplace still does not operate correctly, consult your local Montigo dealer. All service and repairs should be performed by a qualified Technician. All spare parts, optional fans, and optional trim finishes are available from your local Montigo dealer. Page 29...
  • Page 30: Replacement Parts

    RGC1006 LP Gas Valve RGC1005 RGC1005 RGC1005 NG Pilot RPA020 RPA020 RPA020 LP Pilot RPA021 RPA021 RPA021 NG Burner Contact Local Montigo Dealer LP Burner NG Orifice R0R1120 LP Orifice R0R1121 Door RDTH38 RDTH38 Log Base RLGSH38B Log Set RLGSH38 Page 30 XG0816 - 011012.1...
  • Page 31: Appendix

    H*38DF PFC Peninsula Gas Fireplace Appendix Appendix A: Venting Terminations Location Canada* USA** clearance to the termination frame above grade, veranda, porch, deck, or balcony 12 inches 12 inches clearance to top of doors or operable windows 12 inches 12 inches 9 inches 12 inches clearance to sides or bottom of door or operable windows...
  • Page 32: Warranty

    The duration of any implied warranty with respect to this Montigo Gas Appliance is limited to the duration of the foregoing warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above may not apply to you.
  • Page 33: State Of Massachusetts

    H*38DF PFC Peninsula Gas Fireplace Appendix Appendix C: State of Massachusetts Amendment (Gas Fireplace / Equipment sold in the State of Massachusetts) 5.08: Modifications to NFPA-54, Chapter 10 (1) Revise NFPA-54 section 10.5.4.2 by adding a second exception as follows: Existing chimneys shall be permitted to have their use continued when a gas conversion burner is installed, and shall be equipped with a manually reset device that will automatically shut off the gas to the burner in the event of a sustained back-draft (2) Revise 10.8.3 by...
  • Page 34 H38DF PFC Peninsula Gas Fireplace Ferndale, Washington Langley, British Columbia TF: 1.800.789.6236 TF: 1.800.378.3115 FX: 1.866.3000.0927 FX: 1.604.607.6462 XG0816 - 011012.1...

This manual is also suitable for:

Hp38df pfcHl38df pfcHl38df pfc

Table of Contents