F-82
NORMAL OPEN CIRCUIT VOLTAGE WAVEFORM (115VAC SUPPLY)
TROUBLESHOOTING & REPAIR
HIGH IDLE – NO LOAD
16.4 ms
50V
This is the typical auxiliary output
voltage generated from a properly
operating machine. Note that each
vertical division represents 50 volts
and that each horizontal division rep-
resents 5 milliseconds in time.
NOTE: Scope probes are connected
at machine 120 VAC receptacle.
SCOPE SETTINGS
Volts/Div.....................50V/Div.
Horizontal Sweep .....5 ms/Div.
Coupling.............................DC
Trigger.........................Internal
VANTAGE® 400
0 volts
5ms
F-82