F-98
STATOR/ROTOR REMOVAL AND REPLACEMENT PROCEDURE
PROCEDURE
12. Label and remove brush leads #201(-) and
#200B(+) from the brush holder assembly.
(The Piggy-backed leads connect closest to
the stator terminations.) See Figure F.21.
13. Pull the
harness containing plug J30, the
brush leads, and the field bridge rectifier
through the bushing in the firewall.
Figure F.20.
TROUBLESHOOTING & REPAIR
(CONTINUED)
FIGURE F.21 – BRUSHHOLDER LEAD REMOVAL
See
VANTAGE® 400
#201
14. Using a 3/8" wrench, remove the brush holder
assembly.
15. Using the 1/2" wrench, disconnect leads #68A
and #69A at their bolted connections beneath
the power module assembly. Label the leads
for reassembly. Cut any necessary cable ties.
See Figure F.22.
F-98
#200A
#200B