Auxiliary Power And Control Connections; Auxiliary Power Table; 115Vac Duplex Receptacle; Receptacle - Lincoln Electric 10120 Operator's Manual

Table of Contents

Advertisement

A-6
AUXILIARY POWER AND
CONTROL CONNECTIONS
Located at the lower front of the welder behind a
hinged door is a 115VAC duplex receptacle for auxil-
iary power (Domestic and Canadian Models only) and
a 14 Pin MS type receptacle for connection of auxil-
iary equipment such as wire feeders. Also, terminal
strips with 115VAC and connections for auxiliary
equipment are located behind the access panel on the
lower case of the welder. A 220VAC receptacle for a
water cooler (European and Export Models only) is
located on the case back.

AUXILIARY POWER TABLE

Voltage and Circuit Breaker Ratings at Auxiliary Power
Connections for Various Models
Auxiliary
Domestic
Power
Models
Connections
(60Hz)
(230/460/575V/60 Hz) (50/60 Hz)
At Duplex
115V 20A

Receptacle

Terminal strip
115V 20A
terminals 31 & 32
MS-Receptacle
115V 20A
pins A & J
MS-Receptacle
42V 10A
pins I & K
At 220V
No Receptacle
Receptacle
115VAC DUPLEX RECEPTACLE (DOMESTIC AND
CANADIAN MODELS ONLY)
The 115VAC duplex receptacle is protected by a cir-
cuit breaker located below the receptacle (see
Auxiliary Power Table). Receptacle is a NEMA 5-20R
(protected by a 20 amp breaker) on Domestic Models
and a NEMA 5-15R (protected by a 15 amp breaker)
on Canadian Models.
230VAC RECEPTACLE (EUROPEAN AND EXPORT
MODELS ONLY)
A Continental European receptacle is located on the
rear panel for supplying 220VAC to a water cooler.
The receptacle has a protective cover to prevent inci-
dently contact and is a Schuko type. The circuit is pro-
tected by a 2 amp circuit breaker also located on the
rear panel. This circuit is electrically isolated from all
other circuits, but on the European Models one line is
connected to chassis ground.
INSTALLATION
Canadian
European
Export
Model
Models
Models
(50/60 Hz)
115V 15A
No Duplex
No Duplex
115V 15A
115V 15A
115V 15A
115V 15A
Open Circuit
115V 15A
42V 10A
42V 10A
42V 10A
No Receptacle
220V 2A
220V 2A
14 PIN MS TYPE RECEPTACLE
(For MS3106A-20-27PX Plug. L.E.C. Part #S12020-32)
Refer to the figure A.4 for the available circuits in the
14 pin receptacle.
42 VAC is available at receptacle pins I and K.
A 10 amp circuit breaker protects this circuit.
115 VAC is available at receptacle pins A and J
(Domestic, Canadian and Export Models). This circuit
is protected by a circuit breaker (see Auxiliary Power
Table). Note that the 42 VAC and 115 VAC circuits
are electrically isolated from each other. However, on
the European model one line of the 115VAC is con-
nected to chassis ground.
FIGURE A.4 FRONT VIEW OF 14-PIN CONNECTOR
RECEPTACLE
PIN
LEAD NO.
A
32
B
GND
C
2
D
4
E
77
F
76
G
75
H
21
I
41
J
31
K
42
L
---
M
---
N
---
1.
115VAC circuit is not present on IEC 974-1 models.
2.
As shipped from the factory Lead #21 from the 14 Pin connector is
connected to "-21" on the terminal strip. This is the configuration
for positive welding. If welding negative polarity, connect lead #21
to the "+21" connection point on the terminal strip.
CV-655
A-6
FUNCTION
115 VAC
Chassis Connection
Trigger Circuit
Trigger Circuit
Output Control
Output Control
Output Control
2
Work Sense Connection
42 VAC
1.
115 VAC
42 VAC
---
---
---

Advertisement

Table of Contents
loading