A-3
INPuT VOLTAGE RECONNECT
PROCEDuRE
When received directly from the factory, units are con-
nected for, 460 VAC. If 460 VAC is the desired input,
then the machine may be connected to the power sys-
tem without any setup required inside the reconnect
door. For other voltages refer to the instructions locat-
ed on the Reconnect Panel Access Door or follow the
instructions below.
CAuTION
Failure to follow these instructions can cause
immediate failure of components within the
welder.
------------------------------------------------------------------------
1. Open the access door on the left side of the
machine.
2. For 208-230: Position the large switch to 208-230.
For 380-575: Position the large switch to 380-575.
3. Move the "A" lead to the appropriate terminal.
Refer to figure A.1 below.
RECONNECT PROCEDURE
1. BE SURE POWER SWITCH IS OFF.
2. CONNECT LEAD 'A' TO DESIRED
INPUT VOLTAGE RANGE.
575V
440-460V
380-415V
220-230V
208V
3. POSITION SWITCH TO DESIRED INPUT VOLTAGE RANGE.
INSTALLATION
'A'
IF MACHINE CEASES TO OPERATE (NO METER, NO FAN)
AND THERE IS NO OTHER KNOWN FAILURE: CHECK FUSE;
REPLACE WITH SPECIFIED FUSE.
VOLTAGE=380-575V
Figure A.1 Input Voltage Reconnect Instructions

OuTPuT CONNECTIONS

Refer to figure B.1 for the location of the 3-Pin
Remote Receptacle and the Output Terminals.

OuTPuT CAbLES

Select the output cable size based on Table A.1.
Cable Sizes for Combined Length of Electrode and
Work Cable ( Copper Cable Rated at 75°C).
Length
up to 150 ft.(46m)
up to 250 ft.(72m)
.
Disconnect input power before
inspecting or servicing machine.
.
Do not operate with wraparound
removed.
.
Do not touch electrically live parts.
Only qualified persons should install,
use or service this equipment.
ES 276i
TAbLE A.1
Cable Size
1/0 (50mm
)
2
2/0 (70mm
)
2
VOLTAGE=208-230V
A-3