F-69
Retest a machine:
• If it is rejected under test for any reason that requires you to remove any mechanical part which could affect the
machine's electrical characteristics. OR
• If you repair or replace any electrical components.
Mode
Low Idle
High Idle
Output Control
Maximum
Output Control
Maximum
Output Control
Maximum
Maximum
Maximum
230 Volt Receptacle
Open Circuit
Load Volts
Voltage
236 - 255
207 - 245
42 Volt Auxiliary
Open Circuit
Voltage
43 - 50
Slip Ring Volts
40 - 50 VDC
1
OUTPUT CONTROL switch set at MAXIMUM (position 10).
2
Output values of each receptacle can vary within the range shown but must be within 2 volts of each other.
RANGER 9
TROUBLESHOOTING & REPAIR

RETEST AFTER REPAIR

ENGINE OUTPUT
No Load RPM
2150-2250
3700-3750
WELDER DC OUTPUT
Range Switch
Open Circuit
Maximum
WELDER AC OUTPUT
Range Switch
Open Circuit
Maximum
WELDER CV OUTPUT
Range Switch
Open Circuit
Wire Feed CV High
Wire Feed CV Med
Wire Feed CV Low
AUXILIARY POWER RECEPTACLE OUTPUT
Load Amps
39 - 43
AMPHENOL AUXILIARY OUTPUT
Load Volts
40 - 48
FIELD AMPS AND VOLTS
1
Load Volts
Volts
65 - 75
25 - 35
1
Load Volts
Volts
73 - 80
25 - 35
1
Load Volts
Volts
50 - 54
25 - 35
35 - 38
20 - 24
34 - 38
16 - 19
115 Volt Receptacle
Open Circuit
Voltage
118 - 127.5
1
115 Volt Receptacle
Open Circuit
Voltage
115 - 126
Field Amps
5.2 - 5.8 Amps DC
Load RPM
NA
3100-3650
Load Amps
245 - 255
Load Amps
250 - 260
Load Amps
250 - 260
200 - 240
155 - 190
1
2
Load Volts
Load Amps
103 - 122
78 - 83
2
Load Volts
110 - 126
RANGER 9
F-69