1
6
7
8
9

ENGINE CONTROLS

1. RUN/STOP SWITCH: RUN position energizes the
engine prior to starting. STOP position stops the
engine. The oil pressure interlock switch prevents
battery drain if the switch is left in the RUN position
and the engine is not operating.
2. CHOKE: When pulled out, it closes the choke valve
on the engine carburetor for quick starting.
3. START PUSHBUTTON: Energizes the starter
motor to crank the engine.
4. IDLER SWITCH: Has two positions as follows:
A) In the HIGH position, the engine runs at the high
idle speed controlled by the engine governor.
B) In the AUTO position, the idler operates as fol-
lows:
a. When switched from HIGH to AUTO or after
starting the engine, the engine will operate
at high speed for approximately 12 seconds
and then go to low idle speed.
b. When the electrode touches the work or
power is drawn from the auxiliary power
OPERATION
FIGURE B.1 – CASE FRONT PANEL CONTROLS
K NO.- CODE - SERIAL NO.
CHOKE
RUN
Hobbs
QUARTZ
0 0 0 0 0 0
HOURS
STOP
OUTPUT
22 CV
20 CV
155 CC
120 CC
17 CV
85 CC
14 CV
50 CC
12 CV
20 CC
THE LINCOLN ELECTRIC COMPANY CLEVELAND, OHIO USA
WELD MODE
ARC CONTROL
0
-2
CV-WIRE
-4
PIPE
-6
CC-STICK
-8
TOUCH START TIG
SOFT
-10
CIRCUIT
BREAKERS
120 V
SIMULTANEOUS WELDING AND POWER
WELD CURRENT
AUX. POWER
AMPS
WATTS
0
8000
100
5000
150
3000
200
1500
250
0
WELDER OUTPUT RATING
AMPS
DUTY CYCLE
VOLTS
250 DC
100%
25
80V MAX OCV AT RATED 3700 RPM
RANGER 250
G3668
VM
START
HIGH
IDLER
AUTO
24 CV
190 CC
26 CV
220 CC
NRTL/C
28 CV
250 CC
NEUTRAL GROUND TO FRAME
+2
WELD
WIRE FEEDER
TERMINALS ON
VOLTMETER
+4
+6
+8
REMOTELY
CONTROLLED
+10
CRISP
120/240 V
240 V. RECEPTACLE
AMPS
33
21
13
6
0
AUXILIARY POWER RATING
WATTS
DUTY CYCLE
VOLTS
8,000
100%
120/240
AVAILABLE POWER IS REDUCED WHILE WELDING
SINGLE PHASE 60 HZ
receptacles (approximately 100 watts mini-
mum), the engine accelerates and operates
at high speed.
c. When welding ceases or the AC power load
is turned off, a fixed time delay of approxi-
mately 12 seconds starts. If the welding or
AC power load is not restarted before the
end of the time delay, the idler reduces the
engine speed to low idle speed.
d. The engine will automatically return to high
idle speed when the welding load or AC
power load is reapplied.
5. ENGINE ALTERNATOR TROUBLE LIGHT: The
yellow engine alternator light is off when the battery
charging system is functioning normally. If the light
turns on, the alternator or the voltage regulator may
not be operating correctly. The light may also come
on if the battery is not holding a charge. It is normal
for the light to come on while starting the engine.
6. ENGINE HOUR METER: Displays the total time
that the engine has been running. This meter is