Lincoln Electric RANGER 250 SVM150-A Service Manual page 106

Lincoln electric welder user manual
Table of Contents

Advertisement

F-56
POWER CAPACITOR REMOVAL AND REPLACEMENT (continued)
PROCEDURE
1. Perform the Case Cover Removal proce-
dure.
2. Perform the Power Module Capacitor
Discharge procedure.
3. Label all leads for reassembly.
4. With the 7/16" wrench, remove the nuts, lock
washers, and flat washers holding the leads
and straps to the power capacitor terminals.
TROUBLESHOOTING & REPAIR
FIGURE F.24 – POWER CAPACITOR MOUNTING DETAILS
POWER
CAPACITORS
VERTICAL
BAFFLE
RANGER 250
CLAMPS
5. With the slot headed screw driver, loosen the
clamps holding the capacitors to the vertical
baffle.
6. Slip the capacitors out of the vertical baffle.
To reassemble, slide the capacitors into the verti-
cal baffle, observe capacitor polarity and lead ori-
entation, and tighten the holding clamps.
Replace the leads and straps as labeled and
tighten the fasteners to between 50 and 60 in-lbs.
Perform the Case Cover Replacement proce-
dure.
F-56

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ranger 250

Table of Contents