DESCRIPTION
This test will help determine if the power module is shorted. This is a resistance test, not a
voltage test. This test will only help diagnose a problem in the "power" section of the module.
Other PC board components could be faulty.
MATERIALS NEEDED
Volt/Ohmmeter (Analog)
3/8" Wrench or socket wrench
9/16" Wrench
1/2" Wrench
7/16" Wrench
This procedure should take approximately 45 minutes to perform.
TROUBLESHOOTING & REPAIR

POWER MODULE TEST

WARNING
RANGER 250
F-39