Lincoln Electric RANGER 225 GXT Service Manual page 51

Lincoln electric welder user manual
Hide thumbs Also See for RANGER 225 GXT:
Table of Contents

Advertisement

F-11
Observe Safety Guidelines detailed in the beginning of this manual.
PROBLEMS
(SYMPTOMS)
Engine will not go to high idle
when attempting to weld or when
the auxiliary power is loaded.
Welding output and auxiliary
power output is normal when Idler
Switch (S3) is in "HIGH" position.
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely,
contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed.
Call 1-888-935-3877.
TROUBLESHOOTING AND REPAIR
POSSIBLE AREAS OF
MISADJUSTMENT(S)
OUTPUT PROBLEMS
1. Make sure the welding cables
and connections are tight.
2. Automatic idler may not function
if the auxiliary power is loaded
to less than 150 Watts.
CAUTION
RANGER® 225 GXT
RECOMMENDED
COURSE OF ACTION
1. Check for broken or faulty
connections in the sensing
leads (#254). Make sure their
connections are tight at the
Electrode Terminal and also at
the Polarity Switch.
Wiring Diagram.
2. Check lead #3 and #6, making
sure they are looped 2 turns (in
opposite directions) through
the current sensor on the
Printed Circuit Board.
3. The Printed Circuit Board may
be faulty. Replace.
F-11
See

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents