F-6
Observe Safety Guidelines detailed in the beginning of this manual.
PROBLEMS
(SYMPTOMS)
No auxiliary power, weld output is
normal and the engine operates
normally.
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely,
contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed.
Call 1-888-935-3877.
TROUBLESHOOTING AND REPAIR
POSSIBLE AREAS OF
MISADJUSTMENT(S)
OUTPUT PROBLEMS
1. Check circuit breakers CB1
through CB4. Reset if tripped.
2. Make sure the Output Control
(R1) is set at the maximum
position.
3. Check for loose or faulty plug(s)
at the power receptacle(s).
CAUTION
RANGER® 225 GXT
RECOMMENDED
COURSE OF ACTION
1. Check the auxiliary power
receptacles and associated
wires for loose or faulty
connections.
2. Perform the Auxiliary and
Field Winding Voltage Test.
3. Check
for
faulty
breakers and loose or faulty
connections on associated
wiring.