PROCEDURE
No-load test values
High idle (No load) RPM: 3700-3800 RPM (61.7 – 63.3 Hz)
Low idle RPM: 2250-2500 RPM (37.5 – 41.7 Hz)
Weld terminal open Circuit Voltage (OCV):
Weld control at maximum: 70 – 80 VDC
Weld control at minimum: 45 – 60 VDC
Full load test values:
Weld output control set to maximum.
Output amps: 165 – 190, Volts: 21 – 27, RPM: 3300 – 3650
Weld output set to minimum:
Output amps: 40 – 55, Volts: 20 – 28
Auxiliary receptacles with weld output control set to maximum:
230 Volt receptacles:
Load amps: 22. – 25, Volts: 216 – 250 VAC
120 Volt receptacles:
Load amps: 20.2 – 24, Volts: 108 – 130 VAC
NOTE: Values shown above are for a machine that is at normal full load temperature. Readings will
likely be slightly higher if machine is cold.