6. OPERATION
6.5

Open/close detecting section

6.5.1

DF angle open/close detection

• The lever actuator is provided to detect the original size when using the auto document
feeder as the original cover.
• When lowering the reverse automatic document feeder to 15 degree angle or lower, the
angle detection lever for the original cover on the copier will be pressed to turn ON the
angle sensor.
6.5.2

DF open/close detection

• The magnet is installed to detect the open/close of the reverse automatic document
feeder on the copier side.
• The original cover sensor on the copier will turn ON by the magnet when lowering DF.
22
Angle sensor
(PS202)
Theory of Operation Ver. 1.0 Jul. 2009
Magnet
Lever actuator
Original cover sensor (RS201)
A0HUT2C013DA