F-61
Retest a machine:
• If it is rejected under test for any reason that requires you to remove any mechanical part which could affect the
machine's electrical characteristics. OR
• If you repair or replace any electrical components.
Input volts/Phase/Hertz
200/3/60
208/3/60
220/3/60
230/3/60
380/3/60
400/3/60
415/3/60
440/3/60
460/3/60
500/3/60
575/3/60
200/3/50
220/3/50
230/3/50
380/3/50
400/3/50
415/3/50
440/3/50
500/3/50
Mode
Constant Current
Constant Current
Constant Voltage
(FCAW/GMAW)
Constant Voltage
(SUB ARC)
Auxiliary Output (#31-#32)
Auxiliary Output (#31-#32)
Auxiliary Output (#41-#42)
Auxiliary Output (#41-#42)
TROUBLESHOOTING & REPAIR

RETEST AFTER REPAIR

INPUT IDLE AMPS AND WATTS
Maximum Idle Amps
10.9
10.5
9.9
9.5
5.8
5.5
5.3
5.0
4.8
4.4
3.8
19.8
18.0
17.2
10.4
9.9
9.5
9.0
7.9
OPEN CIRCUIT VOLTAGES
Input Hertz
60
50
60
50
60
50
60
50
60
50
IDEALARC DC-400
LINCOLN
ELECTRIC
Maximum Idle KW
Open Circuit Volts
®
F-61
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.2
1.3
1.3
1.3
1.3
1.3
1.3
1.3
1.3
54/58
51/55
42.5/46.5
42.5/46.5
43.5/47.5
43.5/47.5
114/124
109/119
43.8/47.5
42.0/45.6