gas boosTeRs

Do not touch the flue outlet or do not insert any objects into the flue outlet.
Keep flammable materials, spray cans, fuel containers, trees, shrubs and pool chemicals etc, well clear of
the flue outlet.
Do not use the gas types other than those designated on the data plate. For example, do not use Propane/
Butane gas mixtures on appliances marked Propane Gas�
Do not use Propane Gas on appliances marked as Natural Gas and vice versa�

HyDRogen gas

In the case of systems using a vitreous enamel lined cylinder, if the hot water unit is not used for two weeks or
more, a quantity of hydrogen gas, which is highly flammable, may accumulate in the water heater. To dissipate this
safely, it is recommended that a non electrically operated hot tap be turned on for two minutes at a sink, basin, or
bath, but not a dishwasher or other appliance. During this procedure there must be no smoking, open flame or any
electrical appliance operating nearby� If hydrogen is discharged through the tap, it will probably make a sound like
air escaping�

WaTeR TeMpeRaTuRe

The water gets heated by the solar energy contributed from the sun and heats the water until the water at the
base of the storage cylinder reaches approximately 65°C� At this time water at the hot outlet can be up to 88°C�
Continued heating is prevented by the 'No Load' protection, a Thermo-arrestor (TA) valve that prevents water
passing from the cylinder to the collectors� During periods of low solar gain, supplementary heating occurs�
To meet Australian regulatory requirements, supplementary heating must be operational.
IMPORTANT

TuRnIng off THe WaTeR HeaTIng sysTeM

If you plan to be away for only a few nights, we suggest you leave the water heating system switched on� If it is
necessary to switch off the water heater, do so as outlined below:
Electric Boosted Systems
Switch off the electrical supply to the supplementary heating element� The switch is usually marked and
located in the electricity meter box of the dwelling�
Gas Boosted systems
Switch off the electric supply to the gas booster�

TuRnIng on THe WaTeR HeaTIng sysTeM

Electric Boosted system
Switch on the electric supply to the supplementary heating element(s)� The switch is usually marked and
located in the electricity meter box of the dwelling�
Gas Boosted systems
Switch on the electrical supply to the gas booster�
Rinnai
WaRnIngs anD IMpoRTanT InfoRMaTIon
9
CC OIM Issue 9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

SunmasterEquinox

Table of Contents