No.
Definition
504
B
Lower paper tray lift motor malfunction (optional two-tray paper tray unit)
The paper lift sensor fails to activate
twice continuously after the tray lift
motor has been on for 18 seconds.
506
B
Paper feed motor lock (optional paper tray units)
A motor lock signal is not detected for
more than 1.5 s or the lock signal is not
detected for more than 1.0 s during
rotation.
541
A
Fusing thermostat/thermistor open
The fusing temperature detected by the
thermistor is below 10°C for 5 seconds
after the main power switch is turned
on.
542
A
Fusing temperature warm-up error
The fusing temperature does not reach
80°C within 30 seconds after the main
switch is turned on.
543
A
Fusing overheat error
A fusing temperature of over 230°C is
detected for 1 second by the fusing
thermistor.
544
A
Fusing low temperature error
A fusing temperature of lower than
100°C is detected for 1 second by the
fusing thermistor during operation or
stand-by mode.
546
A
Unstable fusing temperature
The fusing temperature does not rise
3 °C or more within 5 seconds after the
fusing lamp has been on over 8
seconds.
547
B
Zero cross signal malfunction
Zero cross signals are not detected
within 5 seconds after the main power
switch is turned on, or are not detected
within 1 second after operation begins.
620
B
Communication error between IOB and ADF
The IOB does not receive a response
from the ADF main board for 4 seconds
or more.
Symptom
4-5
SERVICE CALL CONDITIONS
Possible Cause
• Paper lift sensor defective
• Tray lift motor defective
• Too much load on the drive
mechanism
• Poor tray lift motor connection
• Paper feed motor defective
• Too much load on the drive
mechanism
• Fusing thermostat defective or out of
position
• Fusing thermistor defective or out of
position
• Power supply board defective
• Fusing thermistor defective or out of
position
• Fusing lamp open
• Fusing thermostat open
• Fusing thermofuse open
• Power supply board defective
• Fusing thermistor defective
• Power supply board defective
• Fusing lamp open
• Fusing thermistor defective
• Power supply board defective
• Fusing thermistor open
• Fusing thermostat open
• Thermistor defective
• Power supply unit defective
• Power supply board defective
• IOB defective
• BiCU defective
• Poor connection between the IOB and
ADF main board (DF connector)
• ADF main board defective
• IOB defective