SCANNER SECTION

3.4.9 ADJUSTMENT OF 2ND SCANNER POSITION

Do this procedure after replacing a scanner belt. If you replaced the second
scanner belts, go onto the next section ('Adjustment of 1st and 2nd Scanner
Alignment'.)
[C]
[B]
1. Remove the A(R)DF or platen cover.
2. Remove the operation panel (☛ 3.3.5).
3. Remove the top rear cover (☛ 3.3.7).
4. Loosen the 2 screws [A] holding the 2nd scanner belt in place.
5. Slide the 2nd scanner so that the second hole from the right on each scanner
arm is roughly aligned with the position guide holes [B] on the upper and lower
mainframe rims.
6. Insert the positioning tools [C] into both sets of holes.
NOTE: If the 1st scanner is preventing the pins from fitting in smoothly, loosen
the 1st scanner securing screws and slide the 1st scanner out of the
way (☛ 3.4.10, step 1).
7. Re-tighten the screws loosened in step 1 [A] and remove the positioning tools.
8. Go on to the next section, 'Adjustment of 1st and 2nd Scanner Alignment'.
[A]
3-16
20 February, 2001
[C]
[B]
B039R011.WMF