I Serial Port Connections

G RS-232C Connection
A 9-pin connector is provided with the recorder to communicate with the PC via the RS-232C interface.
IN
8
7
6
5
IN
OUT
OUT
8
7
6
5
AUDIO
VIDEO
Note: Using a conversion cable may malfunction since
this RS-232C is incompatible with USB.
G PS
Data Connection
Note the following when connecting the recorder with PS
1. Place the recorder in the middle of the chain when the System Controller and other devices are connected.
2. Termination must be made at both ends of the chain.
Refer to the manual included with each device for termination.
See page 20, I DATA Port Termination for the recorder.
3. Protocol selection must be set to PS
4. Use the optional RS-485 cable for connection.
Connection examples are shown.
<Case 1 > With System Controller and other devices
18
Personal Computer
D-sub9
or
D-sub25
D-sub9
4
3
2
1
SPOT
OUT
ALARM/REMOTE
4
3
2
1
MULTI
RS-232C
MODE
10/100BASE-T
DATA
SCREEN OUT
Digital Disk Recorder
DATA in the menu setup.
RS-485 Cable
System Controller
IN
8
IN
OUT
OUT
8
AUDIO
Disk Recorder
System Controller
Termination : ON
POWER
ON
SIGNAL GND
OFF
Data devices.
7
6
5
4
3
2
1
SPOT
ON
OUT
ALARM/REMOTE
OFF
7
6
5
4
3
2
1
MULTI
VIDEO
RS-232C
MODE
10/100BASE-T
DATA
SCREEN OUT
DIP Switch
(#5 : OFF, #6 : OFF)
ON
1 2 3 4 5 6
WJ-HD200
DB9
1
2
3
4
5
6
7
8
Frame
Shield
WJ-HD200
DB9
2 (RXD)
3 (TXD)
4 (ER)
5 (GND)
6 (DR)
7 (RTS)
8 (CTS)
RS-485 Cable
POWER
SIGNAL GND
UNIT
POWER
0
ON
OFF
1
Data Multiplex Unit
Termination : ON
MODE
PC
DB9
1
2
3
4
5
6
7
8
Frame
PC
DB25
2 (TXD)
3 (RXD)
6 (DR)
7 (GND)
20 (ER)
5 (CTS)
4 (RTS)
ALARM
ALARM
RESET
SUSPEND
SET UP
ALARM
SUSPEND
SET
ESC
2
3
4
Data Multiplex Unit WJ-MP204