GENERAL INSTALLATION
MACHINE DRAIN LINE
STEP 1: LOCATION OF DRAIN LINE CONNECTION Note:
Refer to Drawing A-1.
The drain line connection on this machine is located at rear of machine in the upper-right-hand comer.
Connection size is 3/4". Use 3/4" reinforced hose.
STEP 2: DRAIN LINE INSTALLATION Note:
Refer to Drawing A-2.
Drain should slope downward on an incline to customer's drain connection. For every 24 inches of drain line,
the drop should be 3" to 4".
Please reference Drawing A-3 to note the IMPROPER drain line installation. Once the drain line is sloping
downward, DO NOT slope the drain line upward again. Doing this would prevent the pump from draining
properly.