SERVICE INSTRUCTIONS

SOLENOID VALVE
P/N 0142100
(110V, used on 60 cycle machine)
To take the valve apart:
Disassembly — These valves may be taken apart by
unscrewing the bonnet and the enclosing tube assembly
from the valve body assembly. See Fig. 3. After
unscrewing, carefully lift off the bonnet and enclosing
tube assembly. Don't drop the plunger. The "O" ring seal
and diaphragm cartridge can now be lifted out.
Be careful not to damage the machined faces while the
valve is apart.
To Reassemble — Place the diaphragm cartridge in the
body with the pilot port extension UP. Hold the plunger
with the synthetic seat against the pilot port. Make sure
the "0" ring is in place, then lower the bonnet and
enclosing tube assembly over the plunger. Screw
bonnet assembly snugly down on the body assembly.
(INCOMING WATER SOLENOID VALVE)
Possible Problems
Pilot Port extension #1 clogged Hole #2
clogged
Remedy
Pass heated straight pin through hole #2 or
clean hole #1