Specifications; Wiring Diagram - Superior DRT4036TEN Installation And Operation Instructions Manual

Superior direct-vent gas fireplace
Table of Contents

Advertisement

DRT4036TEN
• Rating: 33,500 Btu/hr
• Gas Type: Natural Gas Only
• Ignition: Electronic
• Manifold Pressure: 3.5" w.c.
• Minimum Inlet Supply Pressure: 5" w.c.
• Maximum Inlet Supply Pressure: 10.5" w.c.
• Front Orifice: #47
• Rear Orifice: #47
DRT4042TEN
• Rating: 41,000 Btu/hr
• Gas Type: Natural Gas Only
• Ignition: Electronic
• Manifold Pressure: 3.5" w.c.
• Minimum Inlet Supply Pressure: 5" w.c.
• Maximum Inlet Supply Pressure: 10.5" w.c.
• Front Orifice: #42
• Rear Orifice: #44
BATTERY PACK
SIZE
SIZE
"D"
"D"
32

WIRING DIAGRAM

CONTROL MODULE
Bk
Bu Bu
Bk
Bk
Red
Red
Superiorfireplaces.US.com

SPECIFICATIONS

DRT4036TEP
• Rating: 31,000 Btu/hr
• Gas Type: Propane/LP Gas Only
• Ignition: Electronic
• Manifold Pressure: 10" w.c.
• Minimum Inlet Supply Pressure: 11" w.c.
• Maximum Inlet Supply Pressure: 13" w.c.
• Front Orifice: #56
• Rear Orifice: #56
DRT4042TEP
• Rating: 37,000 Btu/hr
• Gas Type: Propane/LP Gas Only
• Ignition: Electronic
• Manifold Pressure: 10.0" w.c.
• Minimum Inlet Supply Pressure: 11" w.c.
• Maximum Inlet Supply Pressure: 13" w.c.
• Front Orifice: #56
• Rear Orifice: #55
PILOT CONNECTORS
Yl
Bn
Bn
Bk
Gn
Og
Bk
REMOTE
RECIEVER
Bn
4 "AA" SIZE
BATTERY
VALVE
THTP
TP
TH
Bu
Yl
Bu
Red
Gn
Og
Bk
BATTERY
RELAY
TO J-BOX
ADAPTER
126721-01B