Superior DRT4036TEN Installation And Operation Instructions Manual page 17

Superior direct-vent gas fireplace
Table of Contents

Advertisement

Equipment
Shutoff Valve
Propane/LP
Supply Tank
Figure 25 - Checking Gas Joints for Propane/LP Gas Fireplace
Equipment
Shutoff Valve
Gas Meter
Figure 26 - Checking Gas Joints for Natural Gas Fireplace
PRESSURE TESTING FIREPLACE GAS CONNECTIONS
1. Open equipment shutoff valve (see Figure 24, page 16).
2. Open propane/LP supply tank valve for propane/LP fireplace
or main gas valve located on or near gas meter for natural gas
fireplace.
3. Make sure control knob of fireplace is in the OFF position.
4. Check all joints from equipment shutoff valve to gas valve (see
Figure 25 or Figure 26). Apply noncorrosive leak detection fluid to
all joints. Bubbles forming show a leak. Correct all leaks at once.
5. Light fireplace (see Operation, page 21). Check all other internal
joints for leaks.
6. Turn off fireplace (see To Turn Off Gas to Appliance, page 21).
126721-01B
FIREPLACE INSTALLATION Continued
Gas Valve
Gas Valve
Superiorfireplaces.US.com
REMOVING/REPLACING GLASS DOOR
CAUTION: Do not operate this fireplace with a bro-
ken glass door panel or without the glass door panel
securely in place. For replacement part information
see Replacement Parts, page 33.
CAUTION: Wear gloves and safety glasses while
handling or removing broken glass. Do not remove if
glass is hot. Keep children and pets away from glass.
WARNING: A barrier designed to reduce the risk
of burns from the hot viewing glass is provided with
this appliance and shall be installed.
WARNING: If fireplace has been running, turn off
fireplace. Let cool before removing glass doors.
WARNING: Do not slam or strike doors. Damage
can result in a hazardous condition.
Removing Glass Door
If replacement of glass is necessary, the entire frame assembly must
be replaced. Gloves must be worn when removing/replacing glass
door. If glass is broken tape remaining glass onto frame before
removing.
1. Remove screens if installed.
2. Open bottom access panel.
3. Unlock 2 door latches on bottom of firebox.
4. Tilt open glass door 45° from the bottom of firebox and lift up to
release door from firebox top retainer (see Figure 27).
Glass
Door
Figure 27 - Removing/Replacing Door
Door
Retainer
Door
Bottom
Latches
Access Panel
Location
17