Shelf Position; Hearths; Installation Of Fire; Unpacking The Fire - Flavel Calibre FBFC**MN2 Installation, Maintenance & User Instructions

Coal effect balanced flue gas fire
Hide thumbs Also See for Calibre FBFC**MN2:
Table of Contents

Advertisement

1.4

SHELF POSITION

The fire may be fitted below a combustible shelf providing there is a minimum
distance of 200mm above the top of the fire and the shelf does not project more
than 150mm. If the shelf overhangs more than 150mm the distance between the
fire and the shelf must be increased by 15mm for every 25mm of additional
overhang over 150mm.
1.5

HEARTHS

This appliance must only be installed on to a concrete or non-combustible hearth.
The hearth material must be a minimum thickness of 12mm with the top surface at
least 50mm above the floor. The hearth must be fitted symmetrically about the fire
opening and have a minimum width of 760mm and a minimum projection of
300mm forwards from the fire opening.
2.1

UNPACKING THE FIRE

Carefully lift the fire out of the carton. Remove the loose item packaging carefully
from the the pack. Check the contents as listed :-
IMPORTANT :
DO NOT UNDER ANY CIRCUMSTANCES USE THIS APPLIANCE IF THE
GLASS PANEL IS BROKEN OR NOT SECURELY FIXED TO THE FIREBOX.
Packing Check List
1 off
Fire box & foam seal / burner assembly
1 off
Boxed ceramic 5 piece fuel bed set
1 off
Flue terminal / pipe unit
1 off
Flue terminal guard
1 off
Loose Items pack including cable fixing kit
1 off
Installation / user manual (combined)
5 off
AA batteries (RC models only)
3 off
AA batteries (EFC models only)
1 off
Rubber grommet (to seal gas aperture used)
2 off
Cabling pipes
1 off
Trim
1 off
Fret & ashpan cover

INSTALLATION OF FIRE

THE CARDBOARD FITMENT THAT IS AT THE TOP OF THE
CONVECTION APERTURE SHOULD NOT BE REMOVED
UNTIL THE APPLIANCE IS FULLY INSTALLED AND READY
TO BE LIT.
SECTION 2
6

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Calibre fbfc**rn3Calibrefbfc**en3Calibrefbfc**mp2

Table of Contents