Removal Of The Control Valve (Rc & Efc Variants); Removal Of The Efc Trim Switch - Flavel Calibre FBFC**MN2 Installation, Maintenance & User Instructions

Coal effect balanced flue gas fire
Hide thumbs Also See for Calibre FBFC**MN2:
Table of Contents

Advertisement

4.5
Removing the control valve (remote & EFC models)
4.5.1
Remove ash-pan, fret assembly / trim or fascia from the front of the fire.
4.5.2
Isolate the gas supply, disconnect the gas control valve to bulkhead
pipe and pilot connection to the valve at the pilot burner. Disconnect
the ignition wire and thermocouple from the pilot.
4.5.3
Pull controls sub assembly forward, disconnect pilot and burner pipe,
remove 2 off screws which secure the control valve to the controls sub
assembly.
4.5.4
Replace in reverse order and carry out a gas tightness test.
4.6
Removing the EFC trim switch
4.6.1
Remove ash-pan, fret assembly / trim or fascia from the front of the fire.
4.6.2
Isolate the gas supply, disconnect the gas control valve to bulkhead
pipe and pilot / thermcouple connections to the pilot. Remove the fire
from the opening.
4.6.3
Pull controls sub assembly forward, disconnect the trim switch lead from
the control board, remove the EFC mounting frame from the fire.
4.6.4
Remove the EFC trim switch from mounting frame via the self adhesive
pad, disconnect the wiring loom.
4.6.5
Replace in reverse order and carry out a gas tightness test.