2.10
REMOVING & REFITTING OF THE GLASS FRAME.
2.10.1
Remove the 2 screws which hold the convection slot cover to the
firebox, as shown below in figure 11.
2.10.2
Remove the burner heat shield by unscrewing the 2 off retaining screws
as shown below in figure 11.
2.10.3
Remove the 4 off M5 retaining nuts as shown below in figure 11.
2.10.4
Remove the 3 off top retaining screws as shown below in figure 11.
2.10.5
Remove the 2 off bottom retaining screws as shown below in figure 11.
2.10.6
Re-assemble in reverse order.
NOTE :
Always ensure that a consistent seal between the combustion
chamber and the glass frame is achieved.
Fig. 11
Glass frame assembly,
secured by 5 off
screws and 4 off M5
retaining nuts
Burner heat
shield, secured by
2 screws
15
Convection slot
cover, secured by 2
screws