3.4
LIGHTING THE APPLIANCE - MANUAL CONTROL VARIANTS
IMPORTANT NOTE : IF THE BURNER IS EXTINGUISHED FOR ANY
REASON YOU MUST ENSURE THAT YOU WAIT A FULL FIVE
MINUTES BEFORE ATTEMPTING TO RE-LIGHT THE FIRE.
WHEN TURNING THE FIRE "OFF" PLEASE ENSURE THAT THE
CONTROL VALVE IS TURNED TO THE "OFF" POSITION AND THE
PILOT FLAME IS EXTINGUISHED. DO NOT LEAVE THE PILOT
FLAME ONLY LIT.
3.4.1
Turn on the gas restrictor at the inlet fitting.
3.4.2
Depress the control knob and turn anti-clockwise to the position marked
pilot. Hold in the control knob for a few seconds to purge the pipe work.
3.4.3
Continue to hold-in the control knob and press the igniter button. If the
burner does not light, continue to press the igniter button until ignition
occurs. Continue to hold the control knob for 5-10 seconds to allow
thermocouple to heat up, if the pilot goes out when the control knob is
released, repeat the lighting sequence.
3.4.4
Turn the control knob in the anti-clockwise direction to the high position
and the main burner will light.
3.4.5
Turn the control knob clockwise to the low position and the gas input
will be reduced to the minimum setting.
3.4.6
Slightly depress the control knob and turn to the pilot position, the main
burner will go out but the pilot will remain lit.
3.4.7
Slightly depress the control knob and turn to the off position, the pilot
will now be extinguished.
3.4.8
After ensuring that the fire is safe to use it should be left on high
position to fully warm up. During this time a slight odour may be
noticed, this is due to the "newness" of the fire and will soon disappear.
Finally, hand the Installation and Maintenance Instructions and the Users
Instructions over to the customer and explain the operation of the fire.
NOTE : THIS APPLIANCE IS DESIGNED TO WORK SAFELY AND
EFFECTIVELY DURING ADVERSE WEATHER CONDITIONS.
HOWEVER, DURING SUCH TIMES FLAME DISTURBANCE
MAY BE NOTICED. THIS IS NORMAL AND DOES NOT
EFFECT OR IMPAIR THE SAFETY OF THE APPLIANCE.