transfers control to a process in that file system. If that file system is corrupted, the boot
program checks the other Kernel/Root File System. If that file system is not corrupted, it is
marked as the one to be activated, the value of RFSINUSE is set to the name of the Signed
Kernel/Root Software Package that was used to install that file system, and control is
transferred to it. If both Kernel/Root File Systems are corrupted, processing halts. The
software checks whether a Signed Application/Library Software Package has been
previously downloaded, and if one is found, the Application Software Package and/or the
Library Software Package is installed if either has a different file name than the currently
installed version, replacing the existing corresponding files in the Application File System.
The downloaded Signed Application/Library Software Package is then deleted. If a new
Signed Application/Library Software Package is not found, the integrity of the application
files is checked. If they are corrupted, files from the Backup Package are installed, replacing
the corrupted files in the Application File System. Any time an Application Software
Package or a Library Software Package is installed, the value of the persistent parameter
APPNAME_IN_USE is set to the file name of the Application Software Package that was
installed. If the application files are not corrupted, or after the Backup Package has been
installed, control is transferred to the application installed in the Application File System.
While loading the application files into volatile memory and as control is transferred to them,
the value of the APPNAME_IN_USE parameter is displayed on the bottom text line.
3. The internal clock/calendar is set to 0:00:00 Saturday, January 1, 2000 and started.
4. The deskphone activates the Ethernet line interface, the PC Ethernet jack, and dial pad
input to allow the invocation of procedures. The activation occurs as soon as possible after
power-up or a reset.
The deskphone displays the speed of the Ethernet interface in Mbps, that is,
10 or 100. The message No Ethernet displays until the software determines whether the
interface is 10 Mbps or100 Mbps.
Note:
The Ethernet speed indicated is the LAN interface speed for both the deskphone
Note:
and any attached PC, assuming the administrator has not disabled the latter
interface by a PHY2STAT setting.
!
Important:
Pressing the Program softkey at any time during startup invokes the Craft
Important:
Access entry procedure to allow manual settings, but only if the PROCSTAT
(local dialpad procedure status) system value is "0" providing full access to local
procedures or if PROCSTAT is "1" in certain instances requiring input. For
information, see
invoked, the startup process terminates. The Program softkey also displays in
conjunction with a message describing a processing conflict, for example, when
an ARP response indicates a conflict in obtaining the IP Address.
Power-Up and Reset Operation (Dynamic Addressing Process)