Power & Reset Page - HP ntegrity iLO 2 MP Operation Manual

Table of Contents

Advertisement

Figure 6-17 Power & Reset Page
NOTE:
The BL c-Class tab is available only on HP Integrity server blades. For information on
how to set the power management options in Onboard Administrator, see the HP BladeSystem
Onboard Administrator User Guide on the HP website at:
http://h20000.www2.hp.com/bc/docs/support/SupportManual/c00705292/c00705292.pdf
Table 6-15
lists the fields, buttons, and descriptions.
Table 6-15 Power & Reset Page Description
Fields and Buttons
System Power
System Power Control
104
Using iLO 2 MP
The current power state of the system.
A user with power control access can issue the following options for remote control of
the system power:
• Power Cycle: Turns system power off and on. The delay between off and on is 30
seconds.
• Power On: Turns system power on (it has no effect if power is already on).
• Power Off: Turns system power off. This is equivalent to forcing the system power
off with the front panel power switch. There is no signal sent to the OS to bring the
software down before power is turned off. For proper system shutdown, shutdown
the OS before issuing this command.
• Graceful Shutdown: BMC sends a signal to the OS to shutdown, prior to turning
off system power supported by IPF operating systems.
Description