Minimum Clearances To Combustibles - Superior DRT6340TYN Installation And Operation Instructions Manual

Superior drt/drc6300 series powervent direct vent gas fireplaces
Table of Contents

Advertisement

INNOVATIVE HEARTH PRODUCTS • POWER VENT DV GAS FIREPLACES (DRT6340/45TYN) • INSTALLATION INSTRUCTIONS

MINIMUM CLEARANCES TO COMBUSTIBLES

Appliance And Vent Clearances
The appliance is approved with zero clearance to combustible materials
on all sides. Refer to Table 5 for minimum clearance values. For typical
installations, see Figure 2 on Page 7.
MINIMUM CLEARANCES
Sides
Top Spacers
Floor
Back
Bottom of Appliance To Ceiling
Vent
SERVICE CLEARANCES Feet (meters)
Front
Table 5
* 3" (75 mm) above any horizontal/inclined vent component.
** See Page 11, Step 1 for clearance requirements to the nailing flange
located at each side of the unit and any screw heads adjacent to it.
Wall Finishes / Surrounds / Mantels
NOTE: Combustible wall finish materials and/or surround materials
must not be allowed to encroach the area defined by the appliance
front face (black sheet metal). Never allow combustible materials to
be positioned in front of or overlapping the appliance face. See Figure
6 and Figure 44 on Page 28.
Noncombustible materials, such as surrounds and other appliance trim,
may be installed on the appliance front face with these exceptions: they
must not cover any portion of the removable glass panel.
Vertical installation clearances to combustible mantels vary according to
the depth of the mantel (see Figure 5). Mantels constructed of noncom-
bustible materials may be installed at any height above the appliance.
Minimum clearance requirements include any projections such as shelves,
window sills, mantels, etc. above the appliance.
NOTE: We recommend the use of high temperature paint (rated 175 °F
or higher) on the underside of the mantel.
10
*
Inches (millimeters)
1/2" (13 mm)
0" (0 mm) Spacers **
0" (0 mm)
0" (0 mm)
1/2" (13 mm)
0" (0 mm) Spacers
64" (1626 mm)
3" (76 mm) Top*
1" (25.4 mm) Sides and Bottom
3 feet (0.9 meters)
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
MANTEL CLEARANCES
Inches (mm)
14
(356)
12
(305)
10
(254)
8
(203)
6
(152)
(102)
NOTE: Hood shown as positioned in louvered
front model. The hood position in the flush
faced front model is lower than shown.
Figure 5 - Minimum Mantel Clearances
Top View of
Fireplace
At 0" minimum
side wall clearance,
one combustible
wall can project to
any length.
Figure 6 - Minimum Distance to Unprotected Side Wall
12 (305) MANTEL
10 (254) MANTEL
8 (203) MANTEL
6 (152) MANTEL
4 (102) MANTEL
TOP OF
2 (51) MANTEL
APPLIANCE
4
Mantel Leg,
Trim, or Wall
3-1/2"
o
45
(89 mm)
Combustible materials
may project beyond
either side of the
fireplace opening as
long as they are kept
within the shaded
"Safe Zone" area.

Advertisement

Table of Contents
loading