Superior DRT6340TYN Installation And Operation Instructions Manual page 28

Superior drt/drc6300 series powervent direct vent gas fireplaces
Table of Contents

Advertisement

INNOVATIVE HEARTH PRODUCTS • POWER VENT DV GAS FIREPLACES (DRT6340/45TYN) • INSTALLATION INSTRUCTIONS
FINISHING REQUIREMENTS
Wall Details
Complete the finished interior wall. To install the appliance facing flush
with the finished wall, position framework to accommodate the thickness
of the finished wall (Figure 44).
Combustible
Finished Wall
Materials
Header
(2x4's)
Combustible
materials are
allowed above
this point on
the face of the
appliance.
10-3/8" Min.
(263 mm)
The gray shaded
area must be
non-combustible
or Dura Rock
1
* Insulation is NOT ALLOWED in the clearance zones around vent compo-
Installations with horizontal terminations which have minimum
nents. Keep this area free from combustible materials.
vertical vent height only will require 4" (102mm) minimum
side clearance as shown in shaded zone above. All other
installations require 1" (25mm) minimum side clearance as
Figure 44 - Finished Wall
specified in Table 4 on Page 5.
* Insulation is NOT ALLOWED in the clearance zones around vent
A hearth extension is not required with this appliance. If a hearth extension
components. Keep this area free from combustible materials.
is used, there are two methods of installation:
28
3" Min.
(76 mm)*
1"
Adaptor Plus 4
(25.4mm)
Feet Vertical
Minimum
Vent (Min.)
& 90° Elbow
Top of
Appliance
Spacers
Top of Door Frame
Fireplace (right side)
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Noncombustible materials, such as surrounds and other appliance trim,
may be installed on the appliance front face with the exceptions.
Vertical installation clearances to combustible mantels vary according to
the depth of the mantel (see Figure 5 on Page 10). Mantels constructed
of noncombustible materials may be installed at any height above the
appliance opening.
Combustible materials may project beyond the side of the fireplace
opening as long as it is kept within the shaded area illustrated in Figure
6 on Page 10.
Finish Combustible
Or Non-Combustible
Material
Floor Panel
Figure 45 - Hearth Extension
NOTE: A finish trim piece is shipped with your fireplace to extend the base
1/2" to be flush with the finish flanges on the side of the fireplace. This
filler is shipped on top of the fireplace wrapped in foam. If desired this
piece can be placed on the base of the fireplace. It is secured with bend
tabs on either side. Lay the extension in front of the base then secure by
bending tabs on each side over to secure to the base. While this piece is
provided it is not required.
Front Face
Of Fireplace

Advertisement

Table of Contents
loading

This manual is also suitable for:

Drc6340tynDrt6345tynDrc6345tyn

Table of Contents