CHAPTER 7: SERVICE PROCEDURES
SOUND
AL
1
1
2
3
J1
PWR
4
GND
3
V1
2
AL
12
9
1
11
8
10
7
FREQUENTLY USED TEST POINTS FOR INTERFACE BOARD P/N 806-5857
Te s t
12V A C Pow er to Controller
24V A C Pow er to Right Module
24V A C Pow er to Lef t Module
12V A C Pow er to Right MBL Relay 50V A C Scale
12V A C Pow er to Lef t MBL Relay
24V A C Pow er to Right High-Limit
24V A C Pow er to Lef t High-Limit
Probe Resistance (Right) *
Probe Resistance (Lef t) *
High-Limit Continuity (Right)
High-Limit Continuity (Lef t)
** Dis conne ct 15-pin har ne s s fr om contr olle r be for e te s ting pr obe circuit.
** Se e Pr obe Re s is tance Char t at e nd of chapte r .
47 SERIES GAS FRYERS
MV
CMP
PWR
PV
2
6
15
12
9
6
14
11
8
5
13
15
10
7
4
K2
K1
STANDING
HEAT
PILOT
RELAY
RELAY
6
3
J2
5
2
4
1
INTERFACE BOARD P/N 806-5857
M e te r
Se tting
50V A C Scale
1 and 3 on J3
50V A C Scale
4 on J5 and GROUND
50V A C Scale
4 on J1 and GROUND
7 on J3 and 9 on J4
50V A C Scale
9 on J3 and 6 on J2
50V A C Scale
12 on J4 and GROUND
50V A C Scale
3 on J2 and GROUND
R x 1000 OHMS 14 on J3 and 10 on J4
R x 1000 OHMS 14 on J3 and 1 on J2
R x 1 OHM
12 on J4 and Wire 13C on Gas V alve
R x 1 OHM
3 on J2 and Wire 12C on Gas V alve
7-3
24V
MV
PV
AL
3
4
5
3
J3
2
1
K3
HEAT
RELAY
12
9
6
3
J4
11
8
5
2
10
7
4
1
Pins
J5
AL
1
V1
2
GND
3
PWR
4
Re s ults
12-18
22-28
22-28
12-18
12-18
22-28
22-28
**
**
0
0