47 SERIES GAS FRYERS
CHAPTER 6: OPERATOR TROUBLESHOOTING
Troubleshooting Fryers Equipped with Controllers Other Than CM III
POWER SWITCH IS
ON. NO LIGHTS ON
CONTROLLER ARE ON.
FRYER DOES NOT
HEAT.
Do other
Verify that fryer is plugged
Verify that circuit breaker
fryers (if present)
Yes
No
in. Press Power Switch
to fryers is ON. Press
operate correctly?
OFF, then back ON.
Power Switch ON.
Does fryer
Does fryer
Yes
Yes
operate properly?
Problem resolved.
operate properly?
No
No
Press Power Switch OFF,
disconnect unit from electrical
power, remove controller and
replace with another known to
be working.
Reconnect unit to
Does fryer
Problem is beyond scope
No
electrical power. Press
operate properly?
of Operator
Power Switch ON.
Troubleshooting.
Yes
Probable cause is
Call Service Technician.
defective controller.
6-3