Frymaster 47 SERIES Installation, Operation, Service, And Parts Manual page 57

Gas fryers
Hide thumbs Also See for 47 SERIES:
Table of Contents

Advertisement

CHAPTER 6: OPERATOR TROUBLESHOOTING
Troubleshooting the FootPrint III Filtration System
Problem resolved.
Call Service Technician.
47 SERIES GAS FRYERS
POWER SHOWER
NOT SPRAYING
PROPERLY.
Move filter handle to the OFF
position. Remove Power Shower
from frypot and verify that o-rings
and seal on inlet are present and in
good condition. Verify that clean-out
screws at each corner of the Power
Shower frame are present and tight.
Verify that the receptacle in the
frypot is not obstructed. Reinstall
Power Shower, ensuring that inlet
seats properly in its receptacle.
Move the filter handle to the ON
postion.
Is the Power
Yes
Shower spraying
properly?
Is the Power
Yes
Shower spraying
properly?
No
Problem is beyond
scope of Operator
Troubleshooting.
6-17
Probable cause is
solidified oil/shortening
No
in the Power Shower
tubing.
Move the filter handle to the OFF
position and remove the unit from the
frypot. Remove the clean-out
screws and place the unit in a pan of
hot water for several minutes to melt
the oil/shortening. Insert a
straightened paper clip or similar
instrument into each hole to clear
any blockages. Replace and tighten
clean-out screws. Reinstall Power
Shower, ensuring that it seats
properly in its receptacle. Move the
filter handle to the ON position.