Table 5-3. Possible Error Messages During Installation or Operation of 4600 Series IP
Telephones—Continued
Error Message
Password Error
Undefined Error
The Message light blinks on
and off, and the telephone
did not complete
registration.
Timeout Error
Resource Error
Incompatible
Failed to set phone IP
address
Error Messages
5-10
Cause/Resolution
CAUSE: An invalid DEFINITY Registration password has been
entered.
RESOLUTION: Re-enter the password if mis-entered initially. If
appropriate, verify proper password with respect to switch
administration.
CAUSE: An error has occurred without an identifiable cause.
RESOLUTION: Conduct Self-test, restart the telephone, and if no
other cause becomes evident, replace the telephone.
CAUSE: The telephone has a hardware fault.
RESOLUTION: Replace the telephone.
CAUSE: Protocol timeout error.
RESOLUTION: Retry. If failure continues, check network
congestion, addresses, etc. to identify cause of timeout.
CAUSE: DEFINITY rejects the registration request.
RESOLUTION: Verify DEFINITY Administration to ensure the
telephone's proper IP address, extension, and password are
being used.
CAUSE: Release 8 of DEFINITY does not support the current
version of the IP Telephone.
RESOLUTION: Upgrade the DEFINITY to Release 9 software.
CAUSE: The 4600 Series Telephone was originally installed on
one switch with Static Addressing, and has subsequently been
installed on another switch with an active DHCP server assigning
dynamic IP addresses.
RESOLUTION: Reset the telephone.