5022-xxx

Registration

Note: If you need to perform alignment or registration, see
The following information is meant to explain the uses for the menu items.
Print registration makes sure the black printing is properly aligned on the page. This is one of the steps in
aligning a new printhead. It is also the first step in aligning the duplex registration. See
on page
3-12.
The settings available are:
Top Margin
Bottom Margin
Left Margin
Right Margin

Skew

Quick Test
Skew
One printhead houses the four color planes. The black plane is aligned to the printer, and the color planes are
internally aligned to black. Adjust the skew mechanically by moving the printhead with a printhead adjustment
screw. See
"Printhead mechanical alignment" on page 4-3
Electronic alignment fine tunes the alignment of the color planes to the black plane once the printhead is
installed. Skew adjustment must be performed before color alignment is attempted. The following illustration
shows proper alignment versus skewed alignment.
Lexmark C52X
Quick Test
Printer Information
Page Count
xx
PSAC
xx
Installed Memory
xxx MB
Processor Speed
xxxMHz
Serial Number
xxxxxxx
CalStat
xxxx
CalSet
x.xx
x.xx
x.xx
x.xx
x.xx
Engine ID
xx
FSpeed
xxx
Printer Revision Levels
Loader
xx.xx.xxxx-x
Kernel
xxx.xx.xxxx-x
Base
xx.xx.xxxx-x
Network
xxx.xx.xxxxx-x
Network Drvr
xx.xx.xxxx-x
Engine
xx.xx.xxxx-x
Font
x.xxxxx-xx.x
3-4
Service Manual
Proper skew
Straight
Margin Settings
Top Margin
= x
Bottom Margin
= x
Left Margin
= x
Right Margin
= x
Skew
= x
Cyan Top Margin
= x
Cyan Left Margin
= xx
Cyan Right Margin
= x
Cyan Skew
= x
Cyan Bow
= x
Yellow Top Margin
= x
Yellow Left Margin
= x
Yellow Right Margin = x
Yellow Skew
= x
Yellow Bow
= x
Magenta Top Margin
= x
Magenta Left Margin
= x
Magenta Right Margin = x
Magent Skew
= x
magenta Bow
= x
Dup Top Margin
= x
Paper Source
= Tray 1
Formatted Size
= xxxxxx
"Printhead alignment" on page
for instructions on setting printhead alignment.