PROBLEM
The hydraulic system is not
working properly.
working properly.
Hydraulic fluid overheating.
Hoses not joined together
properly.
Automatic control valve pin
release mechanism triggered
too soon.
Remote control does not
work.
5--6
SECTION 5 - - FAULT FINDING

HYDRAULIC SYSTEM

POSSIBLE CAUSE
Oil level low.
Hydraulic filter clogged.
Hydraulic system fault.
Fluid level too high or too low.
Fluid filter element clogged.
Incorrect flow regulation.
Wrong male seals.
Automatic release pressure
incorrectly set.
Hoses not connected correctly. Connect hoses correctly.
Check oil flow in half seals.
System overload.
SOLUTION
Top up system.
Replace hydraulic filter.
Contact your dealer.
Top up fluid level.
Replace filter.
Set to lower capacity.
Replace seals with standard
1
ISO
/
connectors available
2 in.
from your dealer.
Adjust automatic release
pressure setting.
Actuate control levers; if pro-
blems persist, replace male
half seals.
Reduce load or use a suitable
cylinder.