Error; 1-7-1.Error Message; Connect Error; Reset The Camera And Try Again - Sony DSC-F828 Adjustment

Hide thumbs Also See for DSC-F828:
Table of Contents

Advertisement

1-7.

ERROR

In case of an error during the execution of adjustment, the Auto-
matic Adjustment Program interrupts the processing at that point,
and displays an error message, and then terminates the program
execution there.
1-7-1.
Error Message
When an error message is displayed, perform the remedy given
below, and then retry adjustment. If the error message is displayed
though the remedy was performed, the circuits will be faulty.

1. Connect Error

Fig. 6-1-69
Symptom
USB communication with the set is abnormal.
• USB cable is not inserted tightly.
Cause
• Power supply is not installed correctly.
• Communication with SEUS is abnormal.
• Disconnect the USB cable once, and then re-
Remedy
connect it tightly and check that the set is in
"USB Mode".
• Install the power supply correctly.
• Start the SEUS and click the
check that the connection state is established.

2. RESET the CAMERA and Try Again

Fig. 6-1-70
Symptom
The camera is not ready for adjustment.
• Data error exists in the camera.
Cause
• Reset the camera.
Remedy
DSC-F828

3. Adjustment Time Out

Symptom
Cause
Remedy

4. Adjustment NG

Symptom
[Connect]
to
Cause
Remedy
6-28
Fig. 6-1-71
Adjustment does not finish within the specified
time.
• Adjustment conditions are wrong.
• Data error exists in the camera.
• Check that the conditions such as a subject
are correct.
• Reset the camera.
This part indicates
the adjustment
item in which
an error occurred.
Fig. 6-1-72
The adjusted data does not become the speci-
fied value.
• Adjustment conditions are wrong.
• Data error exists in the camera.
• Check that the conditions such as a subject
are correct.
• Reset the camera.
This part indicates
the adjustment
item in which
an error occurred.