3. VCO Adjustment (SY-096 board)

Set the VCO free-run frequency. If deviated, the LCD screen will
be blurred.
Mode
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
Note1: A memory stick must be inserted.
Adjusting method:
Order Page Address Data
1
2
8F
84
3
80
00
4
80
02
5
80
01
6
80
00
7
8
80
02
9
10
Note2: If the data is other than "01", adjustment has errors. See the
following table.
Data of page: 80,
address: 02
01
Normally finished
10
Reached an upper limit
20
Reached a lower limit
30
Time out
40
Out of adjustment range
50
Adjustment is impossible
PLAY (
)
Arbitrary
Data of page: 80, address: 02
8F
73
01
Procedure
Check that "1. Data Setting
during EVF System
Adjustments" is performed.
2F
Set the data.
00
Set the data.
00
Set the data.
80
Set the data.
01
Set the data.
Wait for 1 sec.
Read the data, and check it is
"01". (Note2)
Wait for 1 sec.
If finish the EVF system
adjustments, release the data
setting.
(See "1. Data Setting during
EVF System Adjustments".)
Contents of adjustment error

4. Bright Adjustment (SY-096 board)

Set the level of the VIDEO signal for driving the LCD to the specified
value. If deviated, the screen image will be blackish or saturated
(whitish).
Mode
Subject
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
Note1: A memory stick must be inserted.
Adjusting method:
Order Page Address Data
1
2
8F
88
3
80
00
4
80
02
5
80
01
6
80
00
7
8
80
02
9
10
Note2: If the data is other than "01", adjustment has errors. See the
following table.
Data of page: 80,
address: 02
01
Normally finished
10
Reached an upper limit
20
Reached a lower limit
30
Time out
40
Out of adjustment range
50
Adjustment is impossible
6-32
PLAY (
)
Arbitrary
Data of page: 80, address: 02
8F
75
01
Procedure
Check that "1. Data Setting
during EVF System
Adjustments" is performed.
9F
Set the data.
00
Set the data.
00
Set the data.
80
Set the data.
03
Set the data.
Wait for 1 sec.
Read the data, and check it is
"01". (Note2)
Wait for 1 sec.
If finish the EVF system
adjustments, release the data
setting.
(See "1. Data Setting during
EVF System Adjustments".)