Light Value Adjustment - Sony DSC-F828 Adjustment

Hide thumbs Also See for DSC-F828:
Table of Contents

Advertisement

10. Light Value Adjustment

Adjust the standard LV value.
Mode
STILL (P AUTO) (P)
Subject
Clear chart (PTB-1450/PTB-450)
(Standard picture frame)
Measurement Point
Data of page: 10, address: 0C, 0D
Measuring Instrument
Data of page: 6F, address: 65
Adjustment Page
6F
Adjustment Address
65 to 67
Specified value1
0FE0 to 1020
Specified value2
40 to 60
Note1: If the data of page: 60, address: 02 is "01", select page: 60, address:
01, and set data: 00.
Switch setting:
ZOOM .................................................................... WIDE end
Adjusting method:
Order Page Address Data
1
2
3
60
01
0D
4
5
60
02
6
10
0C
7
10
0D
8
10
11
6F
65
Note2: The adjustment data will be automatically input to page: 6F,
address: 65 to 67.
Processing after Completing Adjustments:
Order Page Address Data
1
60
01
00
2
Procedure
Check that "1. Data Setting
during Camera System
Adjustments" is performed.
Check the picture frame. If
deviated, perform "5. or 6.
Picture Frame Setting".
Set the data.
Wait for 2 sec.
Read the data, and check it is
"01". (Note2)
Read the data, and this data is
named D
.
0C
Read the data, and this data is
named D
.
0D
Calculate D
using the
LV
following equation
(Hexadecimal calculation)
× 100 + D
D
= D
LV
0C
0D
Check that D
satisfies the
LV
specified value1.
Read the data, and check it
satisfies the specified value2.
Procedure
Set the data.
If finish the camera system
adjustments, release the data
setting.
(See "1. Data Setting during
Camera System Adjustments".)
6-19